A correct split AC installation has 6 stages. Plan the locations and mount the indoor unit 7 to 8 ft high. Run insulated copper pipes, put the outdoor unit in shade and give the AC its own earthed circuit. Then pressure test, vacuum and run it for 30 minutes.
A new AC cools only as well as it is fitted. We see 2-year-old ACs with weak cooling and high bills. The AC is fine. The fitting is not.
This page lists the steps our technicians follow on every split AC job. Keep it open on fitting day and tick each step. If you want to know what goes wrong when steps are skipped, read the 7-foot rule and common installation mistakes.
Stage 1: Plan before the technician drills
- Check the AC size first. A wrong size cannot be fixed by good fitting. Use the AC tonnage calculator.
- Mark the indoor unit spot on the long wall, so air flows along the length of the room.
- Do not put the indoor unit directly above the bed or behind a curtain.
- Mark the outdoor unit spot as close to the indoor unit as you can. Aim for 15 ft of pipe or less.
- Plan where the drain water goes. It must flow down all the way.
- In a flat, ask the society if they allow drilling and outdoor units on the front wall.
Stage 2: Mount the indoor unit
- Height: 7 to 8 ft from the floor. Cold air falls, so a high unit cools the whole room.
- Gap to ceiling: at least 6 inches. The unit pulls air in from the top.
- Gap to side walls: at least 6 inches, 12 inches is better.
- Level: the technician checks the back plate with a spirit level. A small tilt toward the drain side is correct.
- Wall hole: 2.5 to 3 inches wide, with a slight slope down to the outside so rain does not come in.
Stage 3: Run the copper pipes and the drain
- Use new copper pipes of the size in the brand manual. Do not reuse old pipes from a previous AC.
- Insulate each pipe on its own with 12 to 15 mm foam. Bare pipe drips water and loses cooling.
- Bend pipes with a bender. A kinked pipe restricts gas flow.
- Clamp the pipes every 3 to 4 ft. Cover exposed runs with a PVC channel.
- Make fresh flares with a flaring tool. Tighten the nuts with a torque wrench.
- Slope the drain pipe down by at least 1 inch every 10 ft. Pour a mug of water into the tray to test it.
Stage 4: Place the outdoor unit
- Pick a shaded wall. North or east is best in Ahmedabad.
- If the only spot gets afternoon sun, fit a canopy 2 to 3 ft above the unit with open sides.
- Keep 18 to 24 inches clear in front of the fan. Keep 6 to 12 inches at the sides and back.
- Use a strong stand or bracket with rubber pads. The unit must sit level.
- Do not box the unit into a closed balcony corner. Hot air comes back into the fan.
Stage 5: Electrical work
The AC needs its own circuit from the board. Do not share it with lights or a geyser.
| AC size | MCB (C-curve) | Copper wire |
|---|---|---|
| 1 ton | 16A | 2.5 sq mm |
| 1.5 ton | 20A | 2.5 sq mm (4 sq mm for a long run) |
| 2 ton | 25A | 4 sq mm |
- Use ISI-marked copper wire only.
- Connect a proper earth wire. Earth resistance should be under 5 ohms.
- If your supply drops below 200V in summer, ask about a stabilizer before the first run.
Stage 6: Pressure test, vacuum and test run
- Fill the pipes with dry nitrogen at about 450 psi, or the figure in the brand manual.
- Hold the pressure for 30 minutes. The gauge must not drop.
- Check every joint with soap water.
- Release the nitrogen and connect the vacuum pump.
- Run the vacuum for 30 to 45 minutes, until the gauge reads 500 microns or lower.
- Open the valves and let the gas into the pipes.
- Run the AC for at least 30 minutes on cool mode.
- Check air temperature at the vent. It should be 8 to 12°C below room air after 15 minutes.
- Check that water flows out of the drain pipe and that nothing rattles.
What a fair installation costs in Ahmedabad (2026)
| Item | Typical price |
|---|---|
| Split AC labour | ₹1,500 to ₹2,500 |
| Copper pipe beyond the first 10 ft (up to 1.5 ton) | ₹220 to ₹320 per ft |
| Copper pipe beyond 10 ft (2 ton and above) | ₹300 to ₹400 per ft |
| Extra gas for a pipe run over 25 ft | ₹1,000 to ₹2,000 |
| Outdoor unit stand | ₹600 to ₹1,200 |
| Core cutting through a concrete wall | ₹500 to ₹1,000 |
Get your own estimate item by item with the installation cost calculator below. For a booked job, see our AC installation service.
Keep these papers
- The installation report or certificate with date, installer name and pipe length.
- The warranty card, filled in and registered with the brand.
- The bill for extra pipe and parts.
Brands ask for these papers when you claim warranty on the compressor or PCB.
Common questions
How long does a split AC installation take?
A standard split AC installation takes 2 to 3 hours. Core cutting through concrete, a long pipe run or rope work on a high floor adds 1 to 2 hours.
What height should the indoor unit of a split AC be?
Fit the indoor unit 7 to 8 ft above the floor, with at least 6 inches of gap below the ceiling. In a room with a 9 to 10 ft ceiling, this gives even cooling and easy access for service.
Is a vacuum pump necessary for AC installation?
Yes. The vacuum pump removes air and moisture from the copper pipes. Moisture in the system damages the compressor over time. Ask the technician to show you the gauge reading.
What MCB and wire does a 1.5 ton AC need?
A 1.5 ton split AC needs its own 20A C-curve MCB and 2.5 sq mm copper wire. Use 4 sq mm wire if the run from the board is long or the AC is 2 ton.
Service and repair team
Want a second opinion?
Send us your question on WhatsApp. A technician replies, not a bot.
We reply in about 15 minutes, Mon to Sat, 9 AM to 7 PM.
Read next
How Much Ton AC for My Room? Size Chart 10x12 to 20x20
A 10x12 room needs a 1 or 1.5 ton AC, 12x12 needs 1.5 ton, 12x15 needs 2 ton. Full room size to tonnage chart for Indian summers, with sun and floor rules.
Common AC Problems and Quick Fixes: 10 DIY Checks at Home
AC not cooling, leaking water or making noise? 10 common problems with the cause and a 5 to 15 minute fix. Try these before you pay ₹500 for a visit.
Hitachi AC Features: Which 6 Matter in 45°C Indian Heat