AC stopped working in a heatwave: what to do in the first hour

Updated 19 October 2026 · 5 min read · By the System Designing service team

First keep people cool, then check power, the remote mode, the error code and the outdoor unit. If the outdoor fan or compressor does not start after one restart, switch off and call a technician. A failed capacitor, the most common cause, costs ₹400 to ₹800.

In May and June, Ahmedabad crosses 45°C on many afternoons. That is also when most ACs fail. Our service phone gets 3 to 4 times more breakdown calls on those days.

Most of these faults are small. Some you can check yourself in 15 minutes. This guide tells you what to do, in order, in the first hour.

Minute 0 to 10: keep people safe first

A closed room at 45°C gets dangerous fast for elderly people, babies and anyone with heart or BP problems.

  • Move everyone to the coolest room. This is usually a ground-floor room on the north or east side.
  • Close curtains on sunny windows. Open windows on the shaded side only.
  • Run ceiling and pedestal fans. Give water, buttermilk or ORS every 30 minutes.
  • Use a damp towel on the neck and arms.

Minute 10 to 30: the checks you can do yourself

  1. Check the MCB or the AC switch. Reset it once if it tripped.
  2. Check the remote battery and the mode. It must show Cool (snowflake), not Fan or Dry.
  3. Set 24°C and fan speed High. Do not set 16°C, it does not cool faster.
  4. Look at the indoor unit display. Note any blinking light or code.
  5. Look up the code on our AC error code page. It tells you if the fault is serious.
  6. Pull out the indoor filter. If it is grey with dust, wash it and refit it dry.
  7. Go to the outdoor unit. Check that the fan turns and nothing blocks it.
  8. Switch off, wait 3 minutes, then switch on again. Do this only once.

Minute 30 to 60: read what the outdoor unit tells you

After the restart, stand near the outdoor unit for 5 minutes. What you see tells you the likely fault.

What you seeLikely causeTypical cost
Nothing starts. Indoor unit also dead.Power, MCB, loose wire or PCB₹300 to ₹600 (wire); ₹3,000 to ₹8,000 (PCB)
Outdoor unit hums but fan does not turnFailed capacitor₹400 to ₹800
Runs 10 to 20 minutes, then stopsDirty outdoor coil or low voltage₹500 to ₹1,200 (cleaning) or a stabilizer
Runs all the time, air not cold, ice on pipesLow gas (leak)₹2,000 to ₹4,000 (leak fix and gas)
Loud grinding, burning smell or MCB trips againCompressor or motor fault₹8,000 to ₹15,000; see repair or replace

If the outdoor unit runs for a few minutes and then trips, switch off at the MCB. Rinse the coil gently with a hose and let it rest for 20 minutes. If it is in direct sun, shade it from above. Leave 2 feet of open space on all sides.

When to stop and call a technician

  • The AC stops a second time after your one restart.
  • You smell burning, see sparks, or the MCB trips again.
  • The outdoor unit hums but the fan does not move.
  • The error code points to the compressor, gas or PCB.

When you call, tell the technician the brand, the age of the AC, and the error code. Send a 10-second video of the outdoor unit on WhatsApp. This lets the technician bring the right part and fix it in one visit. See our AC repair service for areas we cover in Ahmedabad.

Do not fall for the big quote

In a heatwave, some technicians quote ₹15,000 for a new compressor when the fault is a ₹500 capacitor. Ask what part failed and ask to see it. If the quote is above ₹6,000, get a second opinion. Use our repair or replace guide before you pay for a big job.

Stop it happening next summer

  • Get a full service in February or March, before the rush.
  • Ask the technician to test the capacitor. A weak one costs ₹400 to change in March.
  • Wash the indoor filter every 2 weeks from April to June.
  • Use a stabilizer if your voltage drops below 200 V in the afternoon.

Most heatwave breakdowns give warnings first. Read the AC warning signs and the common AC problems and fixes so you catch them early.

Common questions

Why does my AC stop working on the hottest afternoons?

Between 2 PM and 5 PM the outdoor unit works hardest and the voltage often drops. A weak capacitor, a dirty outdoor coil or low voltage then stops the compressor.

Can I spray water on the outdoor unit to cool it?

Switch off the AC at the MCB first. Then rinse the coil gently with a hose from the fan side. Do not use a pressure jet and do not spray a running unit.

How much does a capacitor change cost?

Usually ₹400 to ₹800 for the part and fitting. It is the most common heatwave fault we see, and a technician can change it in about 30 minutes.

Is it safe to restart the AC again and again?

No. Wait at least 3 minutes between restarts. If it stops a second time, leave it off and call a technician, because repeated starts can damage the compressor.